informatique:fortinet:start
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
informatique:fortinet:start [2021/08/17 11:01] – [Auto filesystem check] pteu | informatique:fortinet:start [2021/08/19 15:17] – [USB auto-install] restorer en CLI pteu | ||
---|---|---|---|
Line 1306: | Line 1306: | ||
</ | </ | ||
src: https:// | src: https:// | ||
+ | |||
+ | Si le Fortiguard ne se met pas à jour, on peut diagnostiquer avec : | ||
+ | <code bash> | ||
+ | # depuis le VDOM d' | ||
+ | execute ping update.fortiguard.net | ||
+ | |||
+ | diagnose test update info | ||
+ | |||
+ | diagnose debug enable | ||
+ | diagnose debug application update 255 | ||
+ | execute update-ase | ||
+ | execute update-av | ||
+ | execute update-ips | ||
+ | </ | ||
======Diagnostique et debug====== | ======Diagnostique et debug====== | ||
Line 1677: | Line 1691: | ||
execute usb-disk list | execute usb-disk list | ||
| | ||
+ | </ | ||
+ | |||
+ | Et, si la conf/ | ||
+ | <code bash> | ||
+ | execute restore image usb < | ||
+ | execute restore config usb < | ||
</ | </ | ||
======Métrologie/ | ======Métrologie/ |
informatique/fortinet/start.txt · Last modified: 2024/02/28 14:55 by pteu