User Tools

Site Tools


informatique:fortinet:start

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revisionBoth sides next revision
informatique:fortinet:start [2020/03/06 10:04] – [VPN protocols relaying] pteuinformatique:fortinet:start [2020/04/14 10:32] – [get transceiver] pteu
Line 138: Line 138:
       set mtu-override enable       set mtu-override enable
       set mtu 9000       set mtu 9000
 +</code>
 +
 +Afficher les caractéristiques des modules GBIC/SFP* connectés et reconnus :
 +<code bash>
 +get sys interface transceiver port13
 +Interface port13 - SFP/SFP+
 +  Vendor Name  :            Intel Corp
 +  Part No.     :            FTLX8571D3BCVIT
 +  Serial No.   :            XYZ
 +  Measurement  Unit         Value        High Alarm   High Warning Low Warning  Low Alarm
 +  ------------ ------------ ------------ ------------ ------------ ------------ ------------
 +  Temperature  (Celsius)     42.6         78.0         73.0         -8.0        -13.0
 +  Voltage      (Volts)       3.32         3.70         3.60         3.00         2.90
 +  Tx Bias      (mA)          8.07        13.20        12.60         3.00         2.00
 +  Tx Power     (dBm)         -2.0          0.0         -1.0         -7.0         -8.0
 +  Rx Power     (dBm)         -1.9          0.0         -1.0        -18.0        -20.0
 +    ++ : high alarm, + : high warning, - : low warning, -- : low alarm, ? : suspect.
 </code> </code>
  